Abstract:
Objective:To analyze the accuracy of Chongqing Kangchao Z5 B-ultrasound bladder volume measurement scanner (BS) for bladder volume measurement in pelvic tumor radiotherapy,and to explore the clinical value of bladder filling management combined with BS monitoring bladder volume in maintaining the consistency of bladder filling between treatments and reducing target location shift during pelvic radiotherapy.Methods:A total of 30 patients with pelvic tumor radiotherapy were selected and individualized bladder filling assessment was performed for each patient.Bladder filling,modeling,and CT localization were performed under the whole process management.The bladder volume was measured immediately after the CT scan was completed (recorded as BSV2),and the CT scan images were imported into the planning system to sketch the CT scan bladder volume (recorded as CTSV).The correlation and deviation between BSV2 and CTSV in 30 patients were analyzed.Individualized whole process bladder filling management was performed for 30 patients with pelvic tumor,and the bladder volume (recorded as BSV4) was measured by BS immediately after each radiotherapy.The mean value of BSV4 after all radiotherapy (recorded as BSVmean) of each patient was used for correlation analysis with CTSV,and the deviation analysis between BSV4 and CTSV after each radiotherapy was performed.Results:There was a strong correlation between BSV2 (Y) and CTSV (X) in the enrolled 30 patients.The function was Y=24.838+0.959X,and the correlation coefficient R=0.946.The mean deviation (mean±standard deviation) between BSV2 and CTSV was (4.16%±2.43%).There was also a strong correlation between BSVmean (Y) and CTSV (X) in the enrolled 30 patients during the course of treatment,with the function Y=27.115+0.936X,and the correlation coefficient R=0.986.The mean deviation (mean±standard deviation) between BSV4 and CTSV was (4.05%±2.88%).Conclusion:Chongqing Kangchao Z5 B-ultrasound bladder volume measurement scanner has high measurement accuracy and good repeatability,and can be used to monitor bladder volume in pelvic radiotherapy.Combined with bladder filling management in the whole process,it can effectively ensure the consistency of bladder filling between treatments and the stability of target location in precise radiotherapy for pelvic tumors.

References:

[1] 麻亚茹,林茂盛,陈炯佳,等.膀胱和肠道准备情况对前列腺癌放疗精准实施的影响[J].中国辐射卫生,2024,33(02):123-128. MA YR,LIN MS,CHEN JJ,et al.Effects of bladder and intestinal readiness on accurate radiotherapy for prostate cancer[J].Chinese Journal of Radiation Health,2024,33(02):123-128.
[2]ZHANG F,ZHOU M,WANG G,et al.Evaluation of bladder filling effects on the dose distribution during radiotherapy for cervical cancer based on daily CT images[J].Journal of Applied Clinical Medical Physics,2023,24(11):e14097.
[3] 伍嘉颖,陆世培,李存啸,等.盆腔肿瘤放疗执行前膀胱充盈一致性研究[J].中华放射肿瘤学杂志,2021,30(01):61-65. WU JY,LU SP,LI CX,et al.Consistency study of bladder filling before radiotherapy for pelvic tumor[J].Chinese Journal of Radiation Oncology,2021,30(01):61-65.
[4] 李钰,高岩,刘世龙,等.宫颈癌患者的膀胱充盈度一致性对放疗摆位误差的影响[J].中国辐射卫生,2020,29(03):4. LI Y,GAO Y,LIU SL,et al.Effect of bladder filling consistency on radiotherapy positioning error in patients with cervical cancer[J].Chinese Journal of Radiation Health,2020,29(03):4.
[5] NILOOFAR M,SHAHROKH N,SARE H,et al.Dosimetric impact of bladder volume on organs at risk during external beam radiotherapy of cervical cancer[J].Radiation Protection Dosimetry,2023,199(13):1351-1356.
[6] 赵文斌.膀胱注射充盈法在宫颈癌术后放疗技术中的应用研究[D].广州:南方医科大学,2023. ZHAO WB.Application of bladder injection filling method in postoperative radiotherapy for cervical cancer[D].Guangzhou:Southern Medical University,2023.
[7]李国栋,马晓,倪梦嗔.精准定时饮水与膀胱灌注指导在宫颈癌术后调强放疗中的应用[J].现代实用医学,2022,34(01):51-52. LI GD,MA X,NI MC.Application of precise timing drinking water and bladder perfusion guidance in intensity modulated radiotherapy after cervical cancer surgery[J].Modern Practical Medicine,2022,34(01):51-52.
[8] 王颖,赵树宙,尤金强,等.量化饮水与尿量及膀胱充盈训练在宫颈癌患者放疗中的效果[J].国际护理学杂志,2023,42(10):1849-1853. WANG Y,ZHAO SZ,YOU JQ,et al.Effect of quantifying water intake,urine volume and bladder filling training on radiotherapy in patients with cervical cancer[J].International Journal of Nursing,2023,42(10):1849-1853.
[9]靳玉源,郑凯曦,蒋妍.膀胱充盈训练联合量化饮水对宫颈癌调强放疗患者预后的影响[J].中国医刊,2021,56(01):74-77. JIN YY,ZHENG KX,JIANG Y.Effect of bladder filling training combined with quantitative drinking water on prognosis of patients with cervical cancer undergoing intensive-modulated radiotherapy[J].Chinese Journal of Medicine,2021,56(01):74-77.
[10]BAI F,HU QX,YAO XW,et al.A prospective comparative study on bladder volume measurement with portable ultrasound scanner and CT simulator in pelvic tumor radiotherapy[J].Physical and Engineering Sciences in Medicine,2023,47(1):87-97.
[11] HU QX,YAO WX,XU LL,et al.A comparative study of measuring bladder volume in patients with pelvic tumor receiving radiotherapy using a portable bladder scanner made in China and CT analog positioning machine[J].International Journal of Radiation Oncology,Biology,Physics,2023,117(2S):e673.
[12] SHIBATA M,OKADA W,SANO K,et al.Usefulness of an ultrasound system with automatic bladder urine volume measurement using artificial intelligence technology in radiotherapy[J].Nihon Hoshasen Gijutsu Gakkai Zasshi,2022,78(12):1406-1414.
[13]HAMA Y,TATE E.Learning curve for automated ultrasound cystovolumetry in patients with localized prostate cancer[J].Journal of Radiology Nursing,2022,41(3):218-219.
[14] 莫鉴文,李丽森.膀胱容量测量仪在盆腔放疗中的应用研究[J].深圳中西医结合杂志,2021,31(06):86-88. MO JW,LI LS.Application of bladder volume measuring instrument in pelvic radiotherapy[J].Shenzhen Journal of Integrated Chinese and Western Medicine,2021,31(06):86-88.
[15]CROP F,COMTE P,LE TINIER F,et al.Evaluation of an ultrasound bladder scanner in supine and standing position[J].Journal of Applied Clinical Medical Physics,2021,22(12):194-202.
[16]张雪芳,莫杰明,黄军荣,等.基于超声的膀胱容量测定在宫颈癌调强放疗中准确性及其临床意义[J].中国老年学杂志,2021,41(17):3655-3659. ZHANG XF,MO JM,HUANG JR,et al.Accuracy and clinical significance of ultrasound based bladder volume measurement in intensity modulated radiotherapy for cervical cancer[J].Chinese Journal of Gerontology,2021,41(17):3655-3659.
[17]黄家文,张梅芳,傅万凯,等.膀胱不同充盈状态在宫颈癌调强放疗中的应用分析[J].现代肿瘤医学,2023,31(17):3242-3247. HUANG JW,ZHANG MF,FU WK,et al.Application of different filling status of bladder in intensity modulated radiotherapy for cervical cancer[J].Modern Oncology,2023,31(17):3242-3247.
[18] 耿帅,于雪飞,孙钦飞,等.宫颈癌调强放射治疗中膀胱充盈程度对小肠辐射剂量的影响[J].中华肿瘤防治杂志,2021,28(12):949-953. GENG S,YU XF,SUN QF,et al.Effect of bladder filling degree on small intestine radiation dose during intensity modulated radiation therapy for cervical cancer[J].Chinese Journal of Cancer Prevention,2021,28(12):949-953.
[19] COLLEN C,ENGELS B,DUCHATEAU M,et al.Volumetric imaging by megavoltage computed tomography for assessment internal organ motion during radiotherapy for cervical cancer[J].Int J Radiat Oncol Biol Phys,2010,77(5):1590-1595.
[20] 王霁,唐媛媛,华羽晨,等.便携式膀胱扫描仪在宫颈癌患者CT模拟定位及调强放疗中的精准应用[J].东南国防医药,2022,24(01):83-85. WANG J,TANG YY,HUA YC,et al.Accurate application of portable bladder scanner in simulated CT localization and intensity modulated radiotherapy in patients with cervical cancer[J].Southeast Defense Medicine,2022,24(01):83-85.
[21] BEASSE A,BOISBOUVIER S.Benefits and limitations of using a portable ultrasound scanner (bladderscan) in pelvic radiotherapy.Narrative review of the literature[J].Cancer Radiotherapie,2023,27(3):259-265.
[22] TAYLOR A,POWELL ME.An assessment of interfractional uterine and cervicalmotion:implications for radiotherapy target volume definition in gynaecological cancer[J].Radiother Oncol,2008,88(2):250-257.

Memo

Memo:
-
Last Update: 1900-01-01