|Table of Contents|

Effects of different fixation methods on positioning error of breast cancer radiotherapy

Journal Of Modern Oncology[ISSN:1672-4992/CN:61-1415/R]

Issue:
2021 03
Page:
507-511
Research Field:
Publishing date:

Info

Title:
Effects of different fixation methods on positioning error of breast cancer radiotherapy
Author(s):
CAO JingliGAO WenchaoQIN QiLIN HongyuWANG Junliang
Department of Radiotherapy,the Fifth Medical Center of PLA General Hospital, Beijing 100071,China.
Keywords:
breast tumorradiotherapythermoplastic maskpositioning error
PACS:
R737.9
DOI:
DOI:10.3969/j.issn.1672-4992.2021.03.032
Abstract:
Objective:To investigate the application of four different fixation methods for breast cancer radiotherapy positioning,and analyze the positioning accuracy,so as to provide reference for clinical application.Methods:From November 2018 to January 2019,a total of 34 cases of breast cancer radiotherapy patients were selected,which included 20 cases had breast conserving surgery and 14 cases of breast cancer patients after radical surgery(radiotherapy in the supraclavicular region).20 cases of breast cancer patients after breast conserved surgery were divided into group A and group B,A used vacuum pad and head thermoplastic mask fixation,B used breast bracket.14 cases of breast cancer patients after radical surgery were divided into group C and group D,respectively used neck and shoulder thermoplastic mask(C hands side,D hands grasping ears).We can use Philips Bigbore CT to perform positioning scanning,and transfer images to the Varian Ecplipse treatment planning system for reconstruction and plan design.After the first treatment,patients must complete CT scan,so we can register verified image with the planned image,measure the coordinate error of the treatment center,and then use SPSS18.0 statistical software for statistical analysis of the data,then get the positioning error.Results:The positioning errors of group A in the X,Y and Z directions were (1.7±1.9) mm,(2.1±2.9) mm and (2.0±1.2) mm,respectively.The positioning errors of group B in the X,Y and Z directions were (2.8±1.1) mm,(3.7±1.1) mm and (4.8±1.3) mm,respectively.The positioning errors of group C in the X,Y and Z directions were (2.1±1.6) mm,(2.1±1.5) mm and (3.6± 3.1) mm,respectively.The positioning errors of group D in X,Y and Z directions were (1.0± 0.5) mm,(1.9±1.5) mm and (3.6±1.9) mm,respectively.The positioning error of group A in the Y and Z directions was smaller than that of group B(P=0.048,0.038),and there was no significant difference in the positioning error of group A and group B in the X direction(P>0.05).There was no significant difference in the positioning error between C group and D group in the X,Y and Z directions(P>0.05).Conclusion:Radiotherapy for breast cancer conserving surgery,the vacuum pad and head thermoplastic mask fixation can reduce the positioning error compared with the breast bracket.For breast cancer patients after radical surgery,there is no significant difference in positioning error between the two fixation techniques by neck and shoulder mold,so it is recommended to use the ear grasping method to reduce the dose error caused by the connection between adjacent fields.

References:

[1]TORRE LA,TRABERT B,DESANTIS CE,et al.Ovaria cancer statistics,2018[J].Cancer J Clin,2018,68(4):284-296.
[2]Early Breast Cancer Trialists Collaborative Groups(EBCTCG),CORREA C MEGALE P,TAYLOR C,et al.Overiew of the randomized trials of radiotherapy in ductal carcinoma in situ of the breast[J].J Natl Cancer Inst Monogr,2010,2010(41):162-177.
[3]FALCO G,ROCCO N,PROCACCINI E,et al.Breast conserving treatment therapy be avoided our experience[J].Int J Surg,2014,12(Suppl 2):S47-49.
[4]黎艳萍.早期乳腺癌保乳术及术后治疗的研究进展[J].医学综述,2013,19(1):69-71. LI Yanping.Research progress of early breast cancer's conserving surgery and postoperative treatment[J].Medical Recapitulate,2013,19(1):69-71.
[5]于金明,李建彬.乳腺癌保乳术后放射治疗进展[J/CD].中华乳腺病杂(电子版),2007,1(3):3-9. YU Jinming,LI Jianbin.Advances in radiation therapy following breast conserving therapy for breast cancer[J/CD].Chinse Journal of Breast Disease(Electronic Version),2007,1(3):3-9.
[6]徐朋琴,蔡晶,葛彬彬,等.食管癌放疗两种体位固定技术摆位误差的比较[J].临床肿瘤学杂志,2018,23(12):1128-1130. XU PQ,CAI JJ,GE BB,et al.Comparison of positioning errors between two fixation techniques for esophageal cancer radiotherapy[J].Chin Clin Ocol,2018,23(12):1128-1130.
[7]翟延宝,杜武,梁广立.在CBCT下乳腺癌根治术后调强放疗时两种固定方式应用比较分析[J].吉林医学,2019,40(2):203-205. ZHAI YB,DU W,LIANG GL.Application analysis of intensity modulated radiotherapy after radical mastectomy based on CBCT[J].Jilin Medical Journal,2019,40(2):203-205.
[8]FINNIGAN R,LAMPRECHT B,BARRY T,et al.Inter-and intra-fration moyion in sterotacic body radiotherapy for spinal and paraspinal tumours using cone-beam CT and positional correction in six degrees of freedom[J].J Med Imaging Radiat Oncol,2016,60(1):90-92.
[9]石祥礼,刘冉生,张丙新.胸段食管癌图像引导调强放疗摆位误差分析[J].中国现代医学杂志,2016,26(5):90-92. SHI XL,LIU RS,ZHANG BX.Beam position error analysis of image-guided intensity-modulated radiotherapy for thoracic-segment esophageal cancer[J].China Journal of Modern Medicine,2016,26(5):90-92.
[10]徐子海,童蕾,陈磊,等.基于CT Vision 图像引导的乳腺癌术后患者调强放疗摆位误差测量与分析[J].中国医学杂志,2015,32(6):870-873. XU ZH,TONG L,CHEN L,et al.Measurement and analysis of patients' set-up errors in CT Vision images-guided radiotherapy after breast cancer operation[J].Chinese Journal of Medical Physics,2015,32(6):870-873.
[11]彭明尧,周雪宇,周国旗.探讨乳腺癌适形放疗后导致放射性肺炎发生的危险因素[J].名医,2018,65(10):115. PENF MY,ZHOU XY,ZHOU GQ.To explore the risk factors of radiation pneumonia after conformal radiotherapy for breast cancer[J].Renowned Doctor,2018,65(10):115.
[12]董明,陈文彬,李丹明,等.摆位误差对保乳术后放疗计划剂量分布的影响[J].实用癌症杂志,2013,28(2):186-189. DONG M,CHEN WB,LI DM,et al.The influence of set-up errors on dose distribution of radiation therapy therapy planning for patients with breast-conserving surgery[J].The Practical Journal of Cancer,2013,28(2):186-189.
[13]孙学文.乳腺癌放射治疗中两种不同固定技术的效果对比分析[J].中国医药科学,2018,8(11):150-152. SUN XW.Comparative analysis of the effects of two different fixation techniques in breast cancer radiotherapy[J].China Medicine and Pharmacy,2018,8(11):150-152.
[14]赵志斌.比较乳腺癌放疗应用真空垫与乳腺托架两种固定体位的摆位误差[J].医药前沿,2015,5(11):64-65. ZHAO ZB.Comparison of breast cancer radiotherapy applied vacuum pad and the poisoning error of breast bracket[J].Medical Frontier,2015,5(11):64-65.

Memo

Memo:
-
Last Update: 2021-01-02